USER INSTRUCTIONS

EMBLEM


SWITCH ON PROCEDURE

Switches on Processor must be set as follows:-

WR Initially left hand position (to default system).

PPS @ft position (away from LED)

MR Left position (away from LED)

MOH Right hand position (nearest to LED)

1 . Switch on mains.

2. Cheek 5v & 24v LED's are lit.

3. After approximately 5 seconds move WR to right position.

Adjust VR 1 for music on hold.

LED STATE NOTE

CPU Flashes at 5 per sec All OK

Low Batt. No LED All OK

Steady light Batt. Voltage Low.

No. light Term. not connected.

Term. Flash at 5 per sec Term. off hook.

1 Flash at 1 per sec. Term. connected.

PROGRAMMING

Only from station 1 0

1. Press WR (Reset button under function button F]6) display blanks, you are now in programming mode.

TO EXIT PROGRAMMING MODE.

1 . Press CHECK then F16.

Displays P

2. Press WR to save changes. Note that any calls in progress will be cut off at this stage.

Display returns to telephony.


Last revised: January 12, 2001