CONVERTERS RINGING
| |||||||
This Converter Ringing is used when an external extension is fitted to a
Planset N625. This Ringer is powered from the power unit installed to operate the Plansets (Power Unit No. 53A - 10 volt DC). The cover is called a Cover No. 73A and the relay a Relay No. 1475B. The 75v AC output is on Terminals 1 and 8. The 10 volt DC input power is connected to terminals 7 (+) and 3 (-). The relay is connected to terminals 4 and 5. Produced by GEC. Modern equivalents to the GPO Ringers Diagram - N626. Drawing - 91851. Specification - S843.
The cover, shown to the right, normally covers the relay
|
|||||||