HICOM 100 RANGE
| ||||||||||||||||||||||||||||||||
BACKUP BATTERYThis is coloured orange and on 110/120 systems is located on the lower left hand side of the front circuit board. The battery is a 3 volt lithium cell. It is packaged in plastic and located by 4 pins. Only two of the pins make an electrical connection. The pin to the upper left is positive and the lower right pin negative. - Back to top - CIL WORKINGGC IS HOTEL PACKAGE
GEZ IS CIL TO A PRINTER - Back to top - CIL OUTPUTBaud as required, 8 bits, 2 stop, parity none LX 800 printers need DIP switch 2/2 set to the off position. If not, the printer keeps performing page feeds. - Back to top - CALL WAITING TONETO REMOVE TONE THE PHONE WOULD NORMALLY BE MADE A DATA STATION. THIS CAN CAUSE PROBLEMS WITH UNANSWERED TRANSFERRED CALLS RETURNING TO A BUSY DATA TELEPHONE AND THEN BEING CUT OFF BECAUSE THE CALL IS UNABLE TO CAMP ON. INSTEAD, CHANGE THE CALL WAITING TONE TO A 0.1 SECOND BURST OF TONE EVERY 2 MINUTES. S12*05 to 01 99 02 99 80 FOR INTERNAL CALL WAITING TONE S12*09 to 01 99 02 99 80 FOR EXTERNAL CALL WAITING TONE - Back to top - UK AXE10 EXCHANGESWhen using two wire DTMF pot phones on a AXE 10 to AXE 10 exchange call, the call will usually fail. SET S1*64 TO 3 SECONDS If CIL problems occur set POT phones to DTMF - Back to top - PRINTER PROBLEMSIF THE PRINTER BUFFER APPEARS NOT TO COPE AND GIVES A PRINT OUT WITH BITS MISSING. THE PRINTER IS SET TO A FAST SETTING. REDUCE THE BAUD RATE AND CHECK THE PRINTER LEAD. PRINTER CABLE
- Back to top - PASSWORDThe access password for the UK is SH746 (service - hold - 746) - Back to top - PSU SWITCHESOn HICOM 110/120 systems set PSU switch 3 to position 3-1 labelled -24v. This stops raspberry noises on pot phones on lift off. - Back to top - TIMERSRECALL DURATION TIMER - SET S1*47 to 99 DAILING ON AXE 10 EXCHANGES - SET S1*64 to 3 seconds FASTER DTMF CALLS
- REDUCE FROM 240ms TO 80ms CALL CUT OFFS
TURN OFF BT DIAL TONE DETECT - POSSIBLE SOURCE OF CUTTING OFF NO METER PULSE DETECTION ON DIRECTORY ENQUIRY CALLS
PHANTOM CALLS
NO METERED CALLS UNLESS OVER 20 SECONDS DURATION
- Back to top - GC ALARMThe call records on the admin phones on hotel sites need to be cleared as they fill call record buffers, thus causing a GC ALARM. The following must be done from the reception phone:- TO PRINT CALL RECORDS To clear reception phone substitute DSS BUTTON with a * TO CLEAR CALL RECORDS - Back to top - 110/120/125/130 INITIALISATIONINITIALISATION PROCEDURE - FOR UK POWER UP SYSTEM AND WAIT FOR CLOCK TO SHOW. WAIT ANOTHER 60 SECONDS ENTER THE UK COUNTRY CODE SH54721445 ON FIRST STATION (S and H are the Service
& Hold buttons) IT IS ADVISABLE TO REMOVE ALL TJF CABLES EXCEPT THOSE FROM THE FIRST - Back to top - LCRTO ALLOW MERCURY OVERIDE THE FOLLOWING MUST BE SET ON HICOM 110/120 MERCURY DIAL TONE TIMER S1*76* 1=200ms min - Back to top - TOOLS and CABLESTOOLS CABLES
- Back to top - PCSAT & PCSATDIG PROBLEMSThis is the programming software for the analogue range of Hicom switches. PCSAT is used with Hicom 110 & 120 whilst PCSATDIG is used with Hicom 125 & 130. They must be installed on a PC. Data is downloaded from the telephone system and then reloaded after modification. The data can also be saved to disc. Password = sysupdate Common Problems This is normally due to the speed being incorrectly set. The software is set to 9600 on default. If the system has been changed to a lower baud rate then this will either have to match and PC or visa versa. If the site has no call logger printer attached then the system baud rate should be made 9600. A baud rate of 9600 can be programmed from the lowest numbered extension (handset left on hook) by dialling:
- Back to top -
|
||||||||||||||||||||||||||||||||