OMNI & NTX30
| ||||||||||||||||||||||||||||||||||||||||||||||||
OMNI BACKUPOn an S3 with more than 4 PEMS you are unable to backup DB onto one disc. To copy the relevant files use OM A C Disc 2 (ODDB) - GVP%ODDB (8 files) Disc 3 - TVSPEEDCL (1 file) - Back to top - CIL SETUP1200 baud, parity even, 7 bits, 1 stop - Back to top - CLASS OF SERVICESSTANDARD - Back to top - X125 COMPARE PAGESResponse = PAGE - ADDRESS - DISC - MEMORY MAKE MEMORY THE SAME AS THE DISC PAGE = MEMORY PAGE 00 = Ci0 01 = Ci1 03 = CD1 04 = Ci2 05 = Ci3 06 = CD2 07 = CD3 08 = P0i 09 = P1i & P0D - Back to top - CONSOLE CONNECTIONSCONSOLE WIRING CONNECTIONS FOR LEVEL 2/3 MODELS
MDF/TJF KRONE STRIP CONNECTIONS
PRINTER PORT
CIL - NSDC LEAD ATT CARD CON BOX 201 GRD 5A 9A TX 5B 9B RX 6A 10A CONSOLE CONNECTIONS ATT CARD CON BOX 201 DESCRIPTION TRR 2 1A 1A BLDU TRAN 2 1B 1B RCS 2 3A 2A BLDU REC 2 3B 2B TRR 7A 3A ATTENDANT TRAN 7B 3B RCS 9A 4A ATTENDANT REC 9B 4B SPEECH 6A EXTN No / PORT SPEECH 6B V24 OUTPUT GND 5A 9A TX 5B 9B RX 6A 10A CTS 6B UNAVAILABLE 10B UNAVAILABLE FROM PBX PRINTER PORT PRINTER PORT 3 1 7 4 20 5 - Back to top - DO NOT DISTURB PROBLEMSAFTER POWER DOWN ON AN S3 DO NOT DISTURB AND MESSAGE WAITING TONE MAY ACTIVATE. THIS IS RETAINED ON THE SYSTEM AND CANNOT BE CLEARED BY RESTART OR RELOAD. MESSAGE WAITING CAN BE REMOVED BY WRITING TO THE FOLLOWING ADDRESS:-
CD3 86D 00 00
IF A PROBLEM THEN THE ADDRESS WOULD HAVE BEEN 1E 1F THE DO NOT DISTURB (SHOWING AS NO DISTN ON CONSOLES) MUST BE DEACTIVATED FROM TELEPHONE OR CONSOLE. - Back to top - INTERDIGIT PAUSEINTERDIGIT TIMER ON NTX 30 5 seconds is a good setting for this timer. X120 - CD1 8D08 X150 - CD3 1437 suggested minimum is 03 - Back to top - CHANGING DRIVESNTX30 HD & FLOPPY ADDRESSES FOR X125 SYSTEMS 02 = FLOPPY 00 = HARD DRIVE FOR X150 SYSTEMS 02 = FLOPPY 00 = HARD DRIVE - Back to top - HOT LINEPUT EXTN INTO HOTLINE COS - Back to top - HUNT GROUPSTO OPT IN OR OUT *41 - TO OPT OUT *40 - TO OPT BACK IN - Back to top - KRONE STRIP LAYOUTSFERRANTI KRONE STRIPSSLUK CARD (CCTS 0-7)KRONE STRIP PAIR 1 2 3 4 5 6 7 8 9 10 PORT 4 0 5 1 6 2 7 3 - - 16 CIRCUIT SLUK (CCTS 8-16) KRONE STRIP PAIR 1 2 3 4 5 6 7 8 9 10 PORT 8 12 9 13 10 14 11 15 - - TRUNK CARD KRONE STRIP PAIR 1 2 3 4 5 6 7 8 9 10 PORT 0 - 1 - 2 - 3 - - - NORTON KRONE STRIPS SLUK CARD (CCTS 0-7)KRONE STRIP PAIR 1 2 3 4 5 6 7 8 9 10 PORT 0 1 2 3 - - 4 5 6 7 16 CIRCUIT SLUK (CCTS 8-16) KRONE STRIP PAIR 1 2 3 4 5 6 7 8 9 10 PORT 8 9 10 11 - - 12 13 14 15 TRUNK CARD KRONE STRIP PAIR 1 2 3 4 5 6 7 8 9 10 PORT - - - - - - 0 1 2 3 - Back to top - LEVEL 3 PASSWORDSGo to console setup menu and select password option make level 3 password - MTCE This will ensure that the console archives ok HIGH LEVEL PASSWORDS ARE - NOTRON and 160995 - Back to top - MESSAGE WAITINGX163 ADDRESSES FOR MESSAGE WAITING TONE CD3 86D 1E CD3 86E 1F 1F = MACHINE GUN TONE #70 + EXTN No REMOVES #71 + EXTN No ACTIVATES - Back to top - NSDC LEADTHE 25 WAY D TYPE CONNECTOR SHOULD HAVE THE FOLLOWING PINS STRAPPED - Back to top - 16 CIRCUIT SLUKThe PCMFS card in the shelf in which the 16 cct SLUK is fitted must be BOA revision or better. Check for double outriggers and additional krone strips on Ferranti OMNI's. - Back to top - TRUNK HEADER NUMBERSBLDU WITHOUT THE TRUNK BUSY FIELD WORKING On VDU 3 if the extn bldu is working but the trunk bldu is not then check the following addresses:- x153 CD3 08f2 08f3 x163 CD3 08f4 08f5 If a vdu 1, vdu2 or ATEA console then the data should be:- 90 80 if a vdu 3 then the data should be:- 80 90 The only reason to change these addresses is to match them up with the consoles header numbers. This can be changed on a vdu 3 and is found in the secondary menu of the engineering functions using the high level password. - Back to top - TRUNK TYPESLOOP = 8 EARTH = 16 - Back to top - |
||||||||||||||||||||||||||||||||||||||||||||||||
Last revised: October 30, 2022FM |