PXML No. 68 APPROVAL No. S/1412/23/C/020691 (SX20) & S/1000/23/C/020691 (KINSMAN) Click here to see information on BT's withdrawal of Subscribers Private Metering (SPM) Kinsman Sales Brochure - MER3
The console is the same one used by the Mitel SX10E and although
similar looking to that of the SX200 it is incompatible. The system will support LD and MF
telephones with either earth or timed break recall. The Kinsman was withdrawn from BT's
portfolio in 1988.
A Remote Display Unit (pictured to the left) which allows a standard POT telephone
to be used instead of the Console. The Mitel SX20 is an analogue, stored Programme Control (SPC) PABX employing Solid state space-division switching. Much of the equipment incorporated in the SX20 system is common with other Mitel products. The system consists of a metal Chassis and an impact-resistant plastic cover. Simultaneous use of MF4, Rotary Dial and SuperSet 4 Featurephones is possible. with the use of MF4 or Rotary Dial phones being possible on any of the lines, Supersets, however can only be used on selected lines. Automatic Diagnostics execute self checks of the system. Detected faults raise audio and visual alarms. 240V 50hz Mains voltage is converted in the power supply unit to the voltages required by the system. After a mains failure and exhaustion of the battery back-up power three extensions are connected to the public network, two automatically the third manually (See section on Equipment Provision Rules), under these conditions only Rotary Dial Telephones will function, unless the local exchange is capable of receiving MF4 digits, when MF4 telephones may be used. SuperSets will NOT function during total power fail conditions. A 27v dc feed is supplied to extension telephone instruments. The PABX can be used as a host or subsidiary system in accordance with DTI specification 84/011. Where used as a subsidiary, there may be a limited number of facilities available between the two systems. CAPACITIES
The system may be extended with one or two more cards from the following:-
The trunk modules contain two circuits each and these may be Local Exchange Trunks (switchable for Earth or Loop Calling Protocols). SSAC15A or SSD5E Trunks. The SX20/KINSMAN can handle a maximum of twelve simultaneous calls. The system may also include an operators console. NOTES: The above was taken from the PXML Click here for information on the RAM batteries Cabinet key = FS880
SX20 Console INSTALLATION Loading Default data
CPU DIP switch settings
CPU switch settings
Programming Mode
Click here for advice on trouble shooting the SX20 REMOTE DISPLAY UNIT
Printer Lead Wiring
542 ALARMS 01 Power up diagnostics test. 02 Power up or auto diagnostics test. 04 Automatic diagnostics test. 05 Automatic diagnostics test. 10 TK condition. (No loop curr. detected on TKxx). 11 TK condition. (No seize ACK. when TKxx seized). 12 TK condition. (No Release ACK. when TKxx Rlsd). 20 Sp/path stuck at 0 and busied out. 21 Sp/path stuck at high and busied out. 22 Sp/path xx 5/cct. to Sp/path yy both busied. 23 Sp/path xx failure due to DT detector test. 30 Unable to connect Sp/path to Extension xx. 31 Unable to connect Sp/path to TK xx. 40 DT detector x failure and busied out. 4I MF4 gen. x failure and busied out. 42 MF4 rec. x failure and busied. 50 P/fail & reset caused by internal working. 60-69 Software alarms. 63 Defective battery ram. 64 Corrupted non-volatile ram. 80 Trunk held up busy. 543 ALARMS 01 Power up diagnostics test. 02 Power up or auto diagnostics test. 03 Volatile RAM read/write test error. 04 Automatic diagnostics test. 05 Automatic diagnostics test. 10 TK condition. (No loop curr. detected on TKxx). 11 TK condition. (No seize ACK. when TKxx seized). 12 TK condition. (No Release ACK. when TKxx Rlsd). 15 Extension equipment XX B wire permanent earth. 20 Sp/path stuck at 0 and busied out. 21 Sp/path stuck at high and busied out. 22 Sp/path xx 5/cct. to Sp/path yy both busied. 23 Sp/path xx failure due to DT detector test. 30 Unable to connect Sp/path to Extension xx. 31 Unable to connect Sp/path to TK xx. 40 DT detector x failure and busied out. 4I MF4 gen. x failure and busied out. 42 MF4 rec. x failure and busied. 50 P/fail & reset caused by internal working. 60-69 Software alarms. 63 Defective battery ram. 64 Corrupted non-volatile ram. 72 Console dead due to hardware failure or switching to console-less operation 80 Trunk held up busy & will not release. 90 Reader error (data dump and load). 91 Printer dead. 92 Auto wake-up queue full/CIL queue full. Default Feature Access Codes
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||