eric6.gif (7121 bytes)L. M. ERICSSON
SWITCHBOARD OB 1100
 

OB 1100
SWITCHBOARDS FOR LB SYSTEMS

This wall type replaces the OB 110.

The OB 1100 models were renumbered, circa 1939, by the ABH 1103 - ABH 1115 range. See below for more details.

The switches are designed for operation with magneto telephone instruments.

Connections are set up by means of cords. The switches are made for 3, 4, 5, 6, 8, 10, 12 and 15 lines.

The switchboards are fitted in cases of dark stained, polished oak.

The cords are made in two colours: red and grey.  Odd cord circuits have red cords and even cord circuits have grey cords.

The microtelephones are our modern Bakelite type. The generators have 5 magnets. All conductive parts are fitted on insulating material of high quality.

Electric properties.
All switchboards are made for doubles line working but may, of course, also be used for single line working. The induction coils are anti-sidetone connected. The microphone supply has been arranged so that microtelephones without key are used.

The parts belonging to 10 lines, consisting of 10 calling signals and 10 jacks with terminal strip are joined to a separate lines group set.

The necessary parts for one speaking circuit, consisting of one cord circuit with accessories, key, clearing indicator, and terminal base, are joined to a separate switching set.

The parts are simple to fit in the switchboards, which makes extensions very simply to carry out. This, however, does not refer to the smaller types of wall switches which cannot be extended.

All switchboards are fitted with terminals for the lines and consequently the lines are in no case connected direct to the jacks.

Batteries are supplied only on special request. They can be made up of dry cells or storage batteries. The tension of the microphone battery should be 4.5 Volts for all switchboards. The tension of the signalling battery for wall switches and switchboards with drop indicators, combined drop indicators and jacks or indicator jacks should be 4.5 Volts, and for switchboards with visual indicators and all multiple switchboards it should be 6 Volts.

This wall switchboard has fixed mounting and cannot be extended.


Taken from the L. M. Ericsson Catalogue No. 188 (1934)


ABH 1103 to ABH 1115
The OB 1100 range was renumbered as the ABH 1103 to ABH 1115.

Model Lines Cords Height mm Width mm Depth mm Weight Kg
ABH 1103 3 1 175 200 150 7
ABH 1104 4 2 175 200 150 7
ABH 1105 5 2 175 200 150 8
ABH 1106 6 2 225 200 150 8
ABH 1108 8 3 225 200 150 8
ABH 1110 10 3 225 200 150 9
ABH 1112 12 4 335 225 152 15
ABH 1115 15 4 335 225 152 15

Taken from the L. M. Ericsson Catalogue No. 610 (1939)

 

 

 